Photoelectric
Safety Sweep for Movable Shelving
The EZ-Roller 8 movable shelving
system system also has a
photoelectric safety sweep which
consists of two components that work
together; they are the emitter
and
the receiver. The emitter is located
at one end of the long side of the
carriage while the receiver is
located at the opposite end of the
same carriage. In addition to
protecting individuals, the
photoelectric safety sweep also
protects items that may have been
inadvertently left in the aisle.
Once the beam of light has been
interrupted, the Emergency Stop Loop
light is triggered and must be
cleared before the system will
operate.
Motion
Sensors for Movable Shelving
Motion sensors are perfect for
sensing a person moving in and out
of the aisle. Once the motion sensor
has detected a person entering the
aisle, the unit is electronically
halted.
Motor Current
Monitoring System (MCMS)
Another safety feature is the Motor
Current Monitoring System or MCMS.
The MCMS Logic within the
controller
monitors any change in current being
drawn by the motor. Detection of the
change will trigger an immediate
stop command to cease carriage
movement. Basically, a moving
carriage will be stopped when it
encounters an obstruction that
offers twenty-five pounds of
resistance. When you exert the
pressure, the carriage will stop and
the Emergency Stop will begin
flashing.
Additionally,
when the weight of items stored on
the mobile carriage is either
increased or decreased, the change
will automatically be detected by
the controller and the carriage
running and stopping speeds will be
instantaneously adjusted to meet the
new weight load.
|